Calibration Phantoms

Quality Control for Your Protocol.

Catalog and custom calibration phantoms for imaging quality control.
Designed to keep your data accurate, reproducible, and publication-ready.
Manufactured by Phantech.
Patented Technology

Linearly filled in five seconds.

Phantech's patented piece-wise construction enables complex phantoms to be filled linearly — one channel at a time, via a single Luer Lock syringe. No other phantom fills as fast as ours.
  • Eliminates trapped air bubbles
  • Minimises radioactive volume and staff exposure
  • Removes background noise from residual activity pools
  • Dramatically improves image quality

Stock Phantoms

These phantoms are always kept in stock and ship within 2-3 days at an affordable price.

Derenzo Phantom

Linearly filled with fiducial markers for automated analysis in Imalytics. Used to assess signal recovery across varying rod diameters, helping determine the effective resolution of a PET/SPECT system. Available in a variety of rod diameters, the following are kept in stock: D270712, D270715, D270825, D271015, and D271020.

PVC Phantom

Assess partial volume effects and obtain recovery coefficients to apply to in vivo data. Spheres are linearly filled with diameters from 2.5mm to 12mm, including a blank sphere for background normalization.

Registration Phantom

Contains 48 spheres in a linear fill pattern, with a total volume of ~2 mL. Built to test PET/CT or SPECT/CT registration accuracy across scans, giving a consistent, repeatable reference for co-registration workflows. Computes and allows the user to save a differential transform, which can be applied in subsequent scans to correct for registration shift in a consistent manner.

NEMA NU 4-2008 Phantom

Includes rods at 1, 2, 3, 4, and 5 mm diameters, following the NEMA NU 4-2008 standard for preclinical image quality.

Biomouse

Modeled after an in vivo mouse CT dataset, with fillable organ voids for bladder, brain, heart, kidneys, liver, lungs, spleen, and stomach. CT matched for both bone and tissue, and built for automatic segmentation with Imalytics. Standard 25g size, with a flank tumor option available at 300 µL. Test your full in vivo imaging pipeline with known organ activity values.

MR Contrast Comparison Phantom

Six separately addressable volumes: five sample volumes at roughly 650 µL each, plus one background volume at roughly 10 mL. Bubble traps built into every volume, sealed with nylon bolts and o-rings. Molded from a single piece of plastic.

Multi-Isotope Phantom

Three separately addressable volumes, each holding roughly 650 µL, filled independently through Luer lock fittings. One section holds 6 mm rods, another a dense grid of 1 mm and 1.2 mm rods for finer resolution testing. Built with markers for automatic registration in Imalytics. 27 mm diameter, 45 mm length.
Imalytics Preclinical Integration

One-Click Automated QC Analysis.

All Phantech nuclear medicine phantoms ship with built-in fiducial cone markers. These enable seamless co-registration within Imalytics Preclinical, turning multi-hour QC workflows into a single click.

Assess your scanner's performance on homogeneity, resolution, noise, and fusion accuracy — and get results you can trust for publication.
Manual Phantom Analysis
1-4 Hours
With Imalytics Analysis
<5 Minutes

Validated Across All Major Imaging Modalities  

Explore calibration phantoms by modality.

PET/SPECT

Preclinical nuclear medicine phantoms with fiducial cone markers for automated co-registration. Available as NIST-traceable sealed sources via PhanQual.
  • Derenzo resolution phantoms
  • Partial volume correction (PVC) phantoms
  • NEMA image quality phantoms
  • Uniformity & scatter phantoms
  • Clinical Jaszczak phantoms

NIST-Traceable Sealed Sources

Phantoms ship pre-loaded with an accurate activity concentration of select radioisotopes. Fully NIST traceable.
  • Certified activity concentration on delivery
  • No on-site source loading required
  • Compatible with standard QC protocols
  • Available across select catalog phantoms

CT

HU-matched biomimetic phantoms and resolution test phantoms for preclinical CT, designed to reflect realistic tissue contrast and geometry.
  • HU-matched biomimetic phantoms
  • Resolution & noise assessment
  • Multimodal co-registration targets
  • Custom scanner-specific geometries

MRI

Preclinical MRI phantoms with flexible configurations — uniformity, resolution, and multimodal fusion targets.
  • Uniformity phantoms
  • Resolution bar / rod phantoms
  • Multimodal fusion phantoms
  • Custom configurations available

Optical & Emerging

Phantoms for optical imaging, fluorescence microscopy, magnetic particle imaging, and radioluminescence — supporting emerging modalities with the same rigorous construction.
  • 1951 USAF optical line pair phantoms
  • Optical linearity & uniformity phantoms
  • Optical anthropomorphic phantoms
  • Magnetic particle imaging (MPI) phantoms
  • Radioluminescence phantoms
  • Fluorescence microscopy phantoms
Custom Solutions

Built for your protocol, your scanner, your lab.

Custom Phantom Design

Work directly with Phantech's team of engineers and physicists to design phantoms that match your exact scanner geometry, protocol requirements, or experimental setup, from concept to delivery.

B2B & OEM Solutions

Custom phantoms packaged and branded for your imaging system. Phantech specializes in B2B configurations tailored to your scanner's size, spec, and branding requirements.

Ready to see it in action?

Whether you want a software demo, expert analysis services, or help finding the right phantom or scanner — we're here.